Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
2.
Marques, Heloisa Helena de Sousa; Pereira, Maria Fernanda Badue; Santos, Angélica Carreira dos; Fink, Thais Toledo; Paula, Camila Sanson Yoshino de; Litvinov, Nadia; Schvartsman, Claudio; Delgado, Artur Figueiredo; Gibelli, Maria Augusta Bento Cicaroni; Carvalho, Werther Brunow de; Odone Filho, Vicente; Tannuri, Uenis; Carneiro-Sampaio, Magda; Grisi, Sandra; Duarte, Alberto José da Silva; Antonangelo, Leila; Francisco, Rossana Pucineli Vieira; Okay, Thelma Suely; Batisttella, Linamara Rizzo; Carvalho, Carlos Roberto Ribeiro de; Brentani, Alexandra Valéria Maria; Silva, Clovis Artur; Eisencraft, Adriana Pasmanik; Rossi Junior, Alfio; Fante, Alice Lima; Cora, Aline Pivetta; Reis, Amelia Gorete A. de Costa; Ferrer, Ana Paula Scoleze; Andrade, Anarella Penha Meirelles de; Watanabe, Andreia; Gonçalves, Angelina Maria Freire; Waetge, Aurora Rosaria Pagliara; Silva, Camila Altenfelder; Ceneviva, Carina; Lazari, Carolina dos Santos; Abellan, Deipara Monteiro; Santos, Emilly Henrique dos; Sabino, Ester Cerdeira; Bianchini, Fabíola Roberta Marim; Alcantara, Flávio Ferraz de Paes; Ramos, Gabriel Frizzo; Leal, Gabriela Nunes; Rodriguez, Isadora Souza; Pinho, João Renato Rebello; Carneiro, Jorge David Avaizoglou; Paz, Jose Albino; Ferreira, Juliana Carvalho; Ferranti, Juliana Ferreira; Ferreira, Juliana de Oliveira Achili; Framil, Juliana Valéria de Souza; Silva, Katia Regina da; Kanunfre, Kelly Aparecida; Bastos, Karina Lucio de Medeiros; Galleti, Karine Vusberg; Cristofani, Lilian Maria; Suzuki, Lisa; Campos, Lucia Maria Arruda; Perondi, Maria Beatriz de Moliterno; Diniz, Maria de Fatima Rodrigues; Fonseca, Maria Fernanda Mota; Cordon, Mariana Nutti de Almeida; Pissolato, Mariana; Peres, Marina Silva; Garanito, Marlene Pereira; Imamura, Marta; Dorna, Mayra de Barros; Luglio, Michele; Rocha, Mussya Cisotto; Aikawa, Nadia Emi; Degaspare, Natalia Viu; Sakita, Neusa Keico; Udsen, Nicole Lee; Scudeller, Paula Gobi; Gaiolla, Paula Vieira de Vincenzi; Severini, Rafael da Silva Giannasi; Rodrigues, Regina Maria; Toma, Ricardo Katsuya; Paula, Ricardo Iunis Citrangulo de; Palmeira, Patricia; Forsait, Silvana; Farhat, Sylvia Costa Lima; Sakano, Tânia Miyuki Shimoda; Koch, Vera Hermina Kalika; Cobello Junior, Vilson; HC-FMUSP Pediatric COVID Study Group.
Clinics ; 76: e3488, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1350619

RESUMO

OBJECTIVES: To compare demographic/clinical/laboratory/treatments and outcomes among children and adolescents with laboratory-confirmed coronavirus disease 2019 (COVID-19). METHODS: This was a cross-sectional study that included patients diagnosed with pediatric COVID-19 (aged <18 years) between April 11, 2020 and April 22, 2021. During this period, 102/5,951 (1.7%) of all admissions occurred in neonates, children, and adolescents. Furthermore, 3,962 severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection samples were processed in patients aged <18 years, and laboratory-confirmed COVID-19 occurred in 155 (4%) inpatients and outpatients. Six/155 pediatric patients were excluded from the study. Therefore, the final group included 149 children and adolescents (n=97 inpatients and 52 outpatients) with positive SARS-CoV-2 results. RESULTS: The frequencies of sore throat, anosmia, dysgeusia, headache, myalgia, nausea, lymphopenia, pre-existing chronic conditions, immunosuppressive conditions, and autoimmune diseases were significantly reduced in children and adolescents (p<0.05). Likewise, the frequencies of enoxaparin use (p=0.037), current immunosuppressant use (p=0.008), vasoactive agents (p=0.045), arterial hypotension (p<0.001), and shock (p=0.024) were significantly lower in children than in adolescents. Logistic regression analysis showed that adolescents with laboratory-confirmed COVID-19 had increased odds ratios (ORs) for sore throat (OR 13.054; 95% confidence interval [CI] 2.750-61.977; p=0.001), nausea (OR 8.875; 95% CI 1.660-47.446; p=0.011), and lymphopenia (OR 3.575; 95% CI 1.355-9.430; p=0.010), but also had less hospitalizations (OR 0.355; 95% CI 0.138-0.916; p=0.032). The additional logistic regression analysis on patients with preexisting chronic conditions (n=108) showed that death as an outcome was significantly associated with pediatric severe acute respiratory syndrome (SARS) (OR 22.300; 95% CI 2.341-212.421; p=0.007) and multisystem inflammatory syndrome in children (MIS-C) (OR 11.261; 95% CI 1.189-106. 581; p=0.035). CONCLUSIONS: Half of the laboratory-confirmed COVID-19 cases occurred in adolescents. Individuals belonging to this age group had an acute systemic involvement of SARS-CoV-2 infection. Pediatric SARS and MIS-C were the most important factors associated with the mortality rate in pediatric chronic conditions with COVID-19.


Assuntos
Humanos , Recém-Nascido , Criança , Adolescente , COVID-19/complicações , Estudos Transversais , Estudos de Coortes , Síndrome de Resposta Inflamatória Sistêmica , Centros de Atenção Terciária , SARS-CoV-2
3.
Arq. bras. cardiol ; 114(5): 764-772, maio 2020. tab, graf
Artigo em Português | SES-SP, LILACS | ID: biblio-1131232

RESUMO

Resumo Fundamento A despeito da comprovada efetividade do cardioversor-desfibrilador implantável (CDI), as terapias de choque deflagradas pelo dispositivo podem causar níveis elevados de ansiedade e depressão, provocando efeitos deletérios na qualidade de vida. Objetivo Realizar a tradução, adaptação transcultural e validação do instrumento Florida Shock Anxiety Scale (FSAS) para a língua portuguesa falada no Brasil. Métodos Nesse estudo psicométrico, a validade de construto foi realizada pela análise fatorial exploratória (AFE) e confirmatória (AFC) e pela Teoria de Resposta ao Item. Os índices de ajustamento da AFC foram: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) e RMSR (Root Mean Square of Residuals). A confiabilidade foi verificada pelo Alfa de Cronbach, Ômega de McDonald e Greatest Lower Bound. As análises foram realizadas no SPSS 23.0 e Factor 10.8.01, com nível de significância de 5%. Resultados A versão final em português do FSAS foi administrada em 151 portadores de CDI, com idade média de 55,7 ± 14,1 anos e predomínio do sexo masculino. A análise paralela indicou que o FSAS é unidimensional, com variância explicada de 64,4%. As correlações variaram de 0,31 a 0,77; as cargas fatoriais de 0,67 a 0,86 e as comunalidades de 0,46 a 0,74. Os índices de ajustamento da AFC estabeleceram-se acima dos limites de qualidade. Encontramos evidências satisfatórias de confiabilidade da escala FSAS. Conclusão O instrumento FSAS-Br apresentou evidências consistentes de validade e confiabilidade, podendo, portanto, ser utilizado em portadores de CDI do Brasil. (Arq Bras Cardiol. 2020; 114(5):764-772)


Abstract Background In spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. Objective To carry out the translation, cross-cultural adaptation and validation of the Florida Shock Anxiety Scale (FSAS) scale into Brazilian Portuguese. Methods In this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach's Alpha, McDonald's Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used. Results The final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 ± 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS. Conclusions The FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772)


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Ansiedade/diagnóstico , Qualidade de Vida , Inquéritos e Questionários/normas , Desfibriladores Implantáveis/psicologia , Ansiedade/psicologia , Psicometria , Brasil , Reprodutibilidade dos Testes , Análise Fatorial
4.
Ferreira, Juliana C; Ho, Yeh-Li; Besen, Bruno A M P; Malbuisson, Luiz M S; Taniguchi, Leandro U; Mendes, Pedro V; Costa, Eduardo L V; Park, Marcelo; Daltro-Oliveira, Renato; Roepke, Roberta M L; Silva Jr, João M; Carmona, Maria José C; Carvalho, Carlos Roberto Ribeiro; Hirota, Adriana; Kanasiro, Alberto Kendy; Crescenzi, Alessandra; Fernandes, Amanda Coelho; Miethke-Morais, Anna; Bellintani, Arthur Petrillo; Canasiro, Artur Ribeiro; Carneiro, Bárbara Vieira; Zanbon, Beatriz Keiko; Batista, Bernardo Pinheiro De Senna Nogueira; Nicolao, Bianca Ruiz; Besen, Bruno Adler Maccagnan Pinheiro; Biselli, Bruno; Macedo, Bruno Rocha De; Toledo, Caio Machado Gomes De; Pompilio, Carlos Eduardo; Carvalho, Carlos Roberto Ribeiro De; Mol, Caroline Gomes; Stipanich, Cassio; Bueno, Caue Gasparotto; Garzillo, Cibele; Tanaka, Clarice; Forte, Daniel Neves; Joelsons, Daniel; Robira, Daniele; Costa, Eduardo Leite Vieira; Silva Júnior, Elson Mendes Da; Regalio, Fabiane Aliotti; Segura, Gabriela Cardoso; Marcelino, Gustavo Brasil; Louro, Giulia Sefrin; Ho, Yeh-Li; Ferreira, Isabela Argollo; Gois, Jeison de Oliveira; Silva Junior, Joao Manoel Da; Reusing Junior, Jose Otto; Ribeiro, Julia Fray; Ferreira, Juliana Carvalho; Galleti, Karine Vusberg; Silva, Katia Regina; Isensee, Larissa Padrao; Oliveira, Larissa dos Santos; Taniguchi, Leandro Utino; Letaif, Leila Suemi; Lima, Lígia Trombetta; Park, Lucas Yongsoo; Chaves Netto, Lucas; Nobrega, Luciana Cassimiro; Haddad, Luciana; Hajjar, Ludhmila; Malbouisson, Luiz Marcelo; Pandolfi, Manuela Cristina Adsuara; Park, Marcelo; Carmona, Maria José Carvalho; Andrade, Maria Castilho Prandini H De; Santos, Mariana Moreira; Bateloche, Matheus Pereira; Suiama, Mayra Akimi; Oliveira, Mayron Faria de; Sousa, Mayson Laercio; Louvaes, Michelle; Huemer, Natassja; Mendes, Pedro; Lins, Paulo Ricardo Gessolo; Santos, Pedro Gaspar Dos; Moreira, Pedro Ferreira Paiva; Guazzelli, Renata Mello; Reis, Renato Batista Dos; Oliveira, Renato Daltro De; Roepke, Roberta Muriel Longo; Pedro, Rodolpho Augusto De Moura; Kondo, Rodrigo; Rached, Samia Zahi; Fonseca, Sergio Roberto Silveira Da; Borges, Thais Sousa; Ferreira, Thalissa; Cobello Junior, Vilson; Sales, Vivian Vieira Tenório; Ferreira, Willaby Serafim Cassa.
Clinics ; 75: e2294, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1133480

RESUMO

OBJECTIVES: We designed a cohort study to describe characteristics and outcomes of patients with coronavirus disease (COVID-19) admitted to the intensive care unit (ICU) in the largest public hospital in Sao Paulo, Brazil, as Latin America becomes the epicenter of the pandemic. METHODS: This is the protocol for a study being conducted at an academic hospital in Brazil with 300 adult ICU beds dedicated to COVID-19 patients. We will include adult patients admitted to the ICU with suspected or confirmed COVID-19 during the study period. The main outcome is ICU survival at 28 days. Data will be collected prospectively and retrospectively by trained investigators from the hospital's electronic medical records, using an electronic data capture tool. We will collect data on demographics, comorbidities, severity of disease, and laboratorial test results at admission. Information on the need for advanced life support and ventilator parameters will be collected during ICU stay. Patients will be followed up for 28 days in the ICU and 60 days in the hospital. We will plot Kaplan-Meier curves to estimate ICU and hospital survival and perform survival analysis using the Cox proportional hazards model to identify the main risk factors for mortality. ClinicalTrials.gov: NCT04378582. RESULTS: We expect to include a large sample of patients with COVID-19 admitted to the ICU and to be able to provide data on admission characteristics, use of advanced life support, ICU survival at 28 days, and hospital survival at 60 days. CONCLUSIONS: This study will provide epidemiological data about critically ill patients with COVID-19 in Brazil, which could inform health policy and resource allocation in low- and middle-income countries.


Assuntos
Humanos , Pneumonia Viral/diagnóstico , Pneumonia Viral/mortalidade , Pneumonia Viral/terapia , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/mortalidade , Infecções por Coronavirus/terapia , Projetos de Pesquisa , Brasil , Estudos de Coortes , Mortalidade Hospitalar , Estudos Observacionais como Assunto , Pandemias , Betacoronavirus , SARS-CoV-2 , COVID-19 , Hospitais Universitários , Unidades de Terapia Intensiva
5.
Motrivivência (Florianópolis) ; 31(60): [1-21], Nov. 2019.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1050985

RESUMO

Objetiva-se apresentar o processo de construção e avaliação de uma ferramenta educacional destinada a inserir estratégias autorregulatórias, durante a aprendizagem de conteúdos conceituais relacionados ao tema transversal saúde, no currículo de Educação Física do Ensino Médio. Trata-se de uma pesquisa-ação, quali-quantitativa, desenvolvida em um curso de mestrado profissional. Professores da Educação Básica, profissionais da educação e profissionais da saúde, selecionados e instrumentalizados em um curso de extensão, responderam um questionário de avaliação sobre a ferramenta. Os dados quantitativos oriundos das perguntas fechadas desse questionário foram analisados por estatística descritiva. Os dados qualitativos extraídos do espaço para inserção de comentários foram analisados pela análise de conteúdo de Bardin. Os resultados sugerem a aplicabilidade da ferramenta educacional, a potencialidade para melhorar práticas pedagógicas e promover processos autorregulatórios nas aulas da Educação Básica, destacando-se a clareza da linguagem, a organização e os debates possíveis a partir de conteúdos do tema transversal saúde.


This is a sample of a master´s degree dissertation developed in the Graduate Program in XXX at XXX. Herein the objective is to assess the potential of an educational kit based on social cognitive theory (SCT) designed to teach adolescents concepts of healthy food and physical activity habits through physical education classes. Five physical education teaching resources published since 1978 until 2013 have been examined, in order to identify how health concepts have been approached. We reveal that our educational kit is in line with a multidimensional perspective of health and that it is unique, especially given that it enables an active and reflexive participation of students in actions that may foster healthy lifestyles. As a conclusion, it is discussed how SCT, our educational kit and a broad view of health are intertwined.


Este artículo es un recorte de una tesis desarrollada en la Maestría Profesional en XXX del XXX. Uno de los objetivos de la investigación es analizar las potencialidades de un material didáctico fundamentado en la Teoría Social Cognitiva (TSC), para enseñar conceptos de alimentación saludable y de actividad física para adolescentes en las clases de Educación Física Escolar (EFE). Se analizaron cinco materiales didácticos de EFE publicados de 1978 a 2013 para identificar cómo el tema salud es abordado. Señalamos que el material de enseñanza producido en la investigación de Maestría está en consonancia con una mirada multidimensional sobre salud y se difiere de materiales existentes, especialmente, por incentivar la participación activa y reflexiva del estudiante en acciones que pueden favorecer estilos de vida saludables. Presentamos las interfaces entre ese recurso educativo, la TSC y la enseñanza de salud bajo una mirada amplia.

6.
Arq. bras. cardiol ; 112(4): 410-421, Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001291

RESUMO

Abstract Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. Objective: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. Methods: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function ≥ 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. Results: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). Conclusion: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period.


Resumo Fundamento: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bradiarritmias que apresentam função ventricular normal, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação do ventrículo esquerdo (VE), utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação do VD. Métodos: Estudo clínico, randomizado, simples-cego em pacientes adultos com indicação de marca-passo (MP) devido a bradiarritmias e função ventricular sistólica ≥ 0,40. A randomização aleatória (VD vs VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram: o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram: a evolução clínica e alterações ecocardiográficas. Empregou-se os testes Qui-quadrado, Exato de Fisher e t de Student, com nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares. O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. Dos 55 pacientes inicialmente alocados para o grupo VE, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Dentre os 35 pacientes que permaneceram com o cabo-eletrodo no VE, a estimulação frênica foi a complicação mais frequente e foi detectada em 9 (25,7%) pacientes. Na fase de seguimento clínico, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do VE foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos pacientes do grupo VE (p = 0,767). A análise feita pelo Doppler tecidual mostrou que 91,2% dos indivíduos do grupo VD e 68,8% dos do grupo VE apresentaram dissincronia interventricular (p = 0,022). Conclusões: A taxa de sucesso do implante no VE foi baixa e a segurança do procedimento foi influenciada, principalmente, pela alta taxa de estimulação frênica no pós-operatório.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Marca-Passo Artificial/efeitos adversos , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Volume Sistólico , Bradicardia/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Método Simples-Cego , Reprodutibilidade dos Testes , Resultado do Tratamento , Implantação de Prótese/métodos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia
7.
Arq. bras. cardiol ; 111(5): 686-696, Nov. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973794

RESUMO

Abstract Background: Venous obstructions are common in patients with transvenous cardiac implantable electronic devices, but they rarely cause immediate clinical problems. The main consequence of these lesions is the difficulty in obtaining venous access for additional leads implantation. Objectives: We aimed to assess the prevalence and predictor factors of venous lesions in patients referred to lead reoperations, and to define the role of preoperative venography in the planning of these procedures. Methods: From April 2013 to July 2016, contrast venography was performed in 100 patients referred to device upgrade, revision and lead extraction. Venous lesions were classified as non-significant (< 50%), moderate stenosis (51-70%), severe stenosis (71-99%) or occlusion (100%). Collateral circulation was classified as absent, discrete, moderate or accentuated. The surgical strategy was defined according to the result of the preoperative venography. Univariate analysis was used to investigate predictor factors related to the occurrence of these lesions, with 5% of significance level. Results: Moderate venous stenosis was observed in 23%, severe in 13% and occlusions in 11%. There were no significant differences in relation to the device side or the venous segment. The usefulness of the preoperative venography to define the operative tactic was proven, and in 99% of the cases, the established surgical strategy could be performed according to plan. Conclusions: The prevalence of venous obstruction is high in CIED recipients referred to reoperations. Venography is highly indicated as a preoperative examination for allowing the adequate surgical planning of procedures involving previous transvenous leads.


Resumo Fundamento: Obstruções venosas são frequentes em portadores de dispositivos cardíacos eletrônicos implantáveis (DCEI) endocárdicos, mas raramente causam problemas clínicos imediatos. A principal consequência destas lesões é a dificuldade para obtenção de via de acesso para o implante de novos cabos-eletrodos. Objetivos: Determinar a prevalência de lesões venosas em candidatos a reoperações envolvendo o manuseio de cabos-eletrodos, e definir o papel da venografia pré-operatória no planejamento desses procedimentos. Métodos: De abril de 2013 a julho de 2016, 100 pacientes com indicação de troca de cabos-eletrodos, ou mudança no modo de estimulação, realizaram venografia com subtração digital no período pré-operatório. As lesões venosas foram classificadas em: não significativas (< 50%), moderadas (51-70%), graves (71-99%) ou oclusivas (100%), e a circulação colateral, em ausente, discreta, moderada ou acentuada. A estratégia cirúrgica foi definida a partir do resultado deste exame. Empregou-se análise univariada para a pesquisa de fatores de risco relacionados à ocorrência dessas lesões, com nível de significância de 5%. Resultados: Obstruções venosas moderadas foram observadas em 23%, graves em 13% e oclusões em 11% dos pacientes estudados, não sendo identificadas diferenças significativas em sua distribuição em relação ao lado do implante, ou do segmento venoso. A utilidade do exame para definição da tática operatória foi comprovada, sendo que em 99% dos casos, a estratégia cirúrgica estabelecida pode ser executada. Conclusões: A prevalência de obstruções venosas é elevada em portadores de DCEI que serão submetidos a reoperações. A venografia é altamente indicada como exame pré-operatório para o adequado planejamento cirúrgico de procedimentos envolvendo cabos-eletrodos transvenosos previamente implantados.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Reoperação/métodos , Doenças Vasculares/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Flebografia/métodos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Reoperação/normas , Doenças Vasculares/epidemiologia , Prevalência , Estudos Transversais , Constrição Patológica/diagnóstico por imagem , Terapia de Ressincronização Cardíaca/efeitos adversos
8.
Arq. bras. cardiol ; 109(4): 331-339, Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887939

RESUMO

Abstract Background: Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). Objective: This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Methods: Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. Results: All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Conclusion: Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.


Resumo Fundamento: Há poucos estudos caracterizando os desfechos cirúrgicos após implante de marca-passo em neonatos com bloqueio atrioventricular total congênito (BAVTC). Objetivos: Este estudo procurou avaliar os resultados a longo prazo de uma abordagem epicárdica minimamente invasiva com utilização de acesso subxifoide para implante de marca-passo em neonatos. Métodos: Entre julho de 2002 a fevereiro de 2015, 16 neonatos consecutivos foram submetidos a implante de marca-passo epicárdico devido a BAVTC. Entre eles, 12 (75,0%) apresentavam defeitos cardíacos congênitos associados ao BAVTC. Os pacientes tinham uma média de idade de 4,5 ± 5,3 dias e nove (56,3%) eram do sexo feminino. Cabo-eletrodo bipolar revestido com esteroide foi implantado em todos os pacientes através de uma abordagem subxifoide minimamente invasiva e fixado na superfície ventricular diafragmática. O gerador de pulsos foi alojado em uma posição epigástrica submuscular. Resultados: Todos os procedimentos foram realizados com sucesso, sem complicações intraoperatórias ou mortes. O tempo médio de duração das operações foi de 90,2 ± 16,8 minutos. Após seguimento médio de 4,1 ± 3,9 anos e máximo de 12,2 anos, não foram observadas complicações de loja do gerador de pulsos, aumento crônico do limiar de comando, fratura de cabo-eletrodo ou outros problemas relacionados ao sistema de estimulação cardíaca. Três crianças foram submetidas à troca do gerador de pulsos por depleção normal de bateria aos 4,0, 7,2 e 9,0 anos de idade, sem necessidade de troca do cabo-eletrodo ventricular. Houve duas mortes aos 12 e 325 dias após o implante do marca-passo devido a sangramento decorrente do uso de trombolítico e insuficiência cardíaca refratária progressiva, respectivamente. Conclusões: O implante de marca-passo epicárdico através de abordagem subxifoide em neonatos com BAVTC com alojamento epigástrico do gerador de pulsos é tecnicamente viável e associado a excelentes desfechos cirúrgicos e longevidade do cabo-eletrodo de estimulação.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Marca-Passo Artificial , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/congênito , Complicações Pós-Operatórias , Radiografia Torácica , Reprodutibilidade dos Testes , Seguimentos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Eletrodos Implantados , Desenho de Equipamento , Duração da Cirurgia , Bloqueio Cardíaco/cirurgia , Complicações Intraoperatórias , Ilustração Médica
10.
Arq. bras. cardiol ; 107(3): 245-256, Sept. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-796031

RESUMO

Abstract Background: Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the population, which consequently increases the frequency of comorbidities. Objective: To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events. Methods: Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis. Results: A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio [OR] = 4.2), functional class III­-IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3). Conclusions: Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.


Resumo Fundamento: Complicações após procedimentos cirúrgicos em portadores de dispositivos cardíacos eletrônicos implantáveis (DCEI) são um problema emergente devido ao aumento crescente na taxa destes procedimentos e ao envelhecimento da população, com consequente aumento de comorbidades. Objetivos: Identificar as taxas de complicações pós-operatórias, mortalidade e readmissão hospitalar, e pesquisar fatores de risco para a ocorrência desses eventos. Métodos: Registro prospectivo e unicêntrico que incluiu todos os indivíduos submetidos a procedimentos cirúrgicos em DCEI no período de fevereiro a agosto de 2011. Os pacientes foram distribuídos por tipos de procedimento nos seguintes grupos: implantes iniciais (coorte 1), troca de gerador (coorte 2) e procedimentos em cabos-eletrodos (coorte 3). Os desfechos foram avaliados por um comitê independente. Empregou-se a análise univariada e multivariada para a pesquisa de fatores de risco e o método de Kaplan-Meier para análise de sobrevida. Resultados: Foram incluídos 713 pacientes, sendo 333, 304 e 76 distribuídos nas coortes 1, 2 e 3, respectivamente. Complicações pós-operatórias foram detectadas em 7,5%, 1,6% e 11,8% dos pacientes nas coortes 1, 2 e 3, respectivamente (p = 0,014). Durante os 6 meses de seguimento, houve 58 (8,1%) óbitos e 75 (10,5%) readmissões hospitalares. Preditores de readmissão hospitalar incluíram o uso de cardioversor-desfibrilador implantável ( odds ratio [OR] = 4,2), classe funcional III-IV (OR = 1,8) e uso de warfarina (OR = 1,9). Preditores de mortalidade incluíram idade acima de 80 anos (OR = 2,4), disfunção ventricular (OR = 2,2), classe funcional III-IV (OR = 3,3) e uso de warfarina (OR = 2,3). Conclusões: Complicações pós-operatórias, readmissões hospitalares e óbitos foram frequentes. Esses eventos estiveram fortemente relacionados ao tipo de procedimento realizado, tipo de DCEI e gravidade da doença cardíaca do paciente.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Marca-Passo Artificial/efeitos adversos , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiopatias/cirurgia , Complicações Pós-Operatórias/mortalidade , Reoperação/estatística & dados numéricos , Volume Sistólico , Fatores de Tempo , Modelos Logísticos , Estudos Prospectivos , Fatores de Risco , Fatores Etários , Medição de Risco , Estimativa de Kaplan-Meier , Terapia de Ressincronização Cardíaca/mortalidade , Cardiopatias/mortalidade
11.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(2): 73-77, mai.-jun.2016. ilus
Artigo em Português | LILACS | ID: lil-794473

RESUMO

A despeito da utilização de profilaxia antibiótica, tanto nos implantes iniciais como nos procedimentos de reoperação, as taxas de infecção relacionada aos dispositivos cardíacos eletrônicos implantáveis têm aumentadoprogressivamente, causando impacto na mortalidade e custos hospitalares. O tratamento de processos infecciososrelacionados aos dispositivos cardíacos eletrônicos implantáveis consiste na remoção completa do sistema deestimulação cardíaca, associada a terapia antimicrobiana sistêmica e reimplante de um novo dispositivo cardíaco. Neste artigo, relatamos o caso clínico de paciente com infecção na loja do gerador de pulsos sem evidênciasde infecção intravascular. O implante de marcapasso atrioventricular epicárdico subxifoide foi utilizado como estratégia para diminuir o risco de contaminação do novo sistema e facilitar a remoção transvenosa dos eletrodos antigos abandonados sob melhores condições técnicas...


Despite the use of antibiotic prophylaxis at the time of cardiac implantable electronic device implantation or reoperations, rates of cardiac implantable electronic device-related infection have increasedprogressively causing an impact on mortality and treatment costs. The treatment of cardiac implantable electronic device-related infections demands a complete removal of the infected device followed by systemic antimicrobial therapy and reimplantation of a new system. In this article, we report the case of a patient with pulse generator pocket infection without evidence of intravascular infection. Epicardial atrioventricular pacemaker implant through subxiphoid approach was used as a strategy to decrease the risk of contamination of the new system and to facilitate the removal of the abandoned transvenous leads under better technical conditions...


Assuntos
Humanos , Feminino , Adulto , Remoção de Dispositivo , Eletrodos , Infecções/diagnóstico , Infecções/terapia , Marca-Passo Artificial , Pacientes , Bloqueio Atrioventricular/terapia , Próteses e Implantes
12.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.1027-1047.
Monografia em Português | LILACS | ID: biblio-971580
13.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 28(3): 126-132, jul.-set.2015. ilus
Artigo em Português | LILACS | ID: lil-777957

RESUMO

Processos infecciosos relacionados aos dispositivos cardíacos eletrônicos implantáveis estão entre ascomplicações mais graves e de difícil tratamento. A incidência de infecções relacionadas aos dispositivos cardíacoseletrônicos implantáveis pode variar de 1% a 7%, apresentando considerável impacto na morbimortalidade.Estudos recentes têm demonstrado que a adição da tomografia por emissão de pósitrons acoplada à tomografiacomputadorizada aos critérios da Duke University modificados aumenta a sensibilidade e a especificidade dodiagnóstico de infecção relacionada aos dispositivos cardíacos eletrônicos implantáveis. Neste artigo relatamos ocaso clínico de um paciente com suspeita de endocardite relacionada a cabo-eletrodo transvenoso abandonado eressincronizador cardíaco epicárdico em uso, em que os achados da tomografia por emissão de pósitrons acopladaà tomografia computadorizada utilizando fluordesoxiglucose 18F ajudaram o correto entendimento do processo ea condução do tratamento cirúrgico...


Infections related to implantable electronic cardiac devices are among the most serious and most difficult to treat complications. The incidence of infections related to cardiac devices may vary from 1% to 7% and result in significant impact on morbidity and mortality. Recent studies have shown that positron emission computed tomography in combination with the modified Duke criteria, increases the sensitivity and specificity of the diagnosis of infections related to cardiac implantable electronic devices. In this article, we report the clinical case of a patient with suspected infectious endocarditis related to an abandoned endocardial pacemaker lead and epicardial cardiac resynchronization, whose 18F-fluoro-2-deoxyglucose positron emission tomography combinedto computed tomography findings were useful for a proper understanding of the process and to guide the surgicaltreatment...


Assuntos
Humanos , Masculino , Criança , Endocardite Bacteriana , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/métodos , Terapia de Ressincronização Cardíaca/métodos , Tomografia por Emissão de Pósitrons/métodos , Bloqueio Atrioventricular/complicações , Tratamento Farmacológico , Ventrículos do Coração , Infecções/complicações , Infecções/diagnóstico , Valva Mitral , Valva Tricúspide
14.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 28(1): 36-39, jan.-mar.2015.
Artigo em Português | LILACS | ID: lil-773031

RESUMO

Dentre as complicações relacionadas aos dispositivos cardíacos eletrônicos implantáveis, os processosinfecciosossão os de maior gravidade e de mais difícil tratamento. A taxa média de infecções relacionadas a esses dispositivoscardíacos relatada na literatura pode variar de 1% a 7% e resultam em importante impacto na morbimortalidade.Neste artigo relatamos o caso clínico de um paciente com infecção crônica relacionada a cabo-eletrodo epicárdicoabandonado, com manifestações recorrentes, em que os achados da tomografia por emissão de pósitrons acoplada atomografia computadorizada utilizando 18F-fluoro-2-deoxiglicose ajudaram o correto entendimentodo processo e acondução do tratamento cirúrgico.


Among the complications related to cardiac implantable electronic devices, infections are the mostserious and more difficult to treat. The mean rate of infections related to these cardiac devices reported in theliterature ranges from 1% to 7% and result in significant impact on morbidity and mortality. We report theclinical case of a patient with chronic infection related to abandoned epicardial pacemaker lead, with recurrentmanifestations, in which the findings of 18F-fluoro-2-deoxyglucose positron-emission tomography combinedwith a multidetection helical computed tomography were useful for a proper understanding of the process and toguide the surgical treatment.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/terapia , Marca-Passo Artificial/efeitos adversos , Ecocardiografia , Eletrocardiografia , Tomografia por Emissão de Pósitrons
15.
Arq. bras. cardiol ; 104(1): 67-77, 01/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741133

RESUMO

Background: Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation. Objectives: To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling. Methods: This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%. Results: A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0) Conclusions: The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling. .


Fundamento: O bloqueio atrioventricular congênito isolado (BAVCi) é raro e tem múltiplas apresentações clínicas. O remodelamento ventricular pode ocorrer em cerca de 10% dos indivíduos após o implante de marca-passo. Objetivos: Avaliar a capacidade funcional de crianças e adultos jovens com BAVCi e estimulação crônica no ventrículo direito (VD) e pesquisar sua associação com fatores preditores de remodelamento ventricular. Métodos: Estudo transversal em coorte de indivíduos com BAVCi e estimulação no VD há mais de um ano. Os indivíduos foram submetidos a avaliação clínica e ecocardiográfica. A capacidade funcional foi avaliada pelo teste de caminhada de seis minutos. Foram empregados os testes qui-quadrado, exato de Fisher e coeficiente de correlação de Pearson, considerando o nível de significância de 5%. Resultados: De março de 2010 a dezembro de 2013, foram avaliados 61 indivíduos, 67,2% do sexo feminino, com 7-41 anos de idade e uso de MP há 13,5 ± 6,3 anos. O percentual de estimulação ventricular era 97,9 ± 4,1% e a duração do complexo QRS estimulado era de 153,7 ± 19,1 ms. A maioria (95,1%) era assintomática e não utilizava medicamentos. A distância média percorrida de 546,9 ± 76,2 m teve forte correlação com a distância predita (r = 0,907; p = 0,001) e não se associou com os fatores de risco de remodelamento estudados. Conclusões: A capacidade funcional de portadores de BAVTCi com estimulação crônica no VD foi satisfatória e não se correlacionou com os fatores de risco para remodelamento ventricular. .


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Adulto Jovem , Bloqueio Atrioventricular/reabilitação , Estimulação Cardíaca Artificial/métodos , Teste de Esforço , Bloqueio Cardíaco/congênito , Marca-Passo Artificial , Disfunção Ventricular Direita/reabilitação , Bloqueio Atrioventricular/fisiopatologia , Estudos Transversais , Ecocardiografia , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/reabilitação , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Direita/fisiopatologia , Remodelação Ventricular/fisiologia , Caminhada/fisiologia
16.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(4): 259-263, Out.-Dez.2014. ilus
Artigo em Português | LILACS | ID: lil-760042

RESUMO

Os autores relatam o caso de criança de 8 anos de idade com discordâncias atrioventricular e ventriculoarterial (transposição corrigida das grandes artérias) e insuficiência cardíaca congestiva crônica refratária, que apresentava retardo da ativação de ventrículo morfologicamente direito em posição sistêmica. A dissincroniacardíaca foi provocada pela estimulação ventricular exclusiva para o tratamento de bloqueio atrioventricular totalconsequente a fechamento de defeito do septo interventricular e correção de regurgitação da valva atrioventricular.O implante do marcapasso atriobiventricular foi realizado por técnica híbrida, transtorácica e transvenosa, e a tática operatória foi definida com o auxílio de tomografia computadorizada do tórax. Após 4 anos de seguimento, a criança mantém melhora tanto clínica como funcional, a despeito da coexistência de alterações em bioprótese valvar e ventrículo anatomicamente direito sob regime pressórico sistêmico...


We report a case of an eight-year-old child, with congenitally corrected transposition of the great arteries and refractory congestive heart failure, who presented a delay in the activation of morphologically right ventricle in systemic position. Cardiac dyssynchrony was caused by isolated ventricular pacing for treatment of total atrioventricular block due to ventricular septal defect closure and correction of atrioventricular valve regurgitation. The atriobiventricular pacemaker was implanted using hybrid, transthoracic and transvenous access, and the surgical strategy was guided by thoracic computerized tomography. After four years of follow-up, we observed clinical and functional improvement, despite of the co-existence of bioprosthetic valve dysfunction and a morphologically right ventricle under systemic conditions...


Assuntos
Humanos , Masculino , Criança , Terapia de Ressincronização Cardíaca , Criança , Cardiopatias Congênitas , Transplante de Coração , Ecocardiografia/métodos , Insuficiência Cardíaca/terapia , Valva Mitral , Marca-Passo Artificial , Transposição dos Grandes Vasos/terapia , Disfunção Ventricular
17.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(1): 53-57, jan.-mar.2014.
Artigo em Português | LILACS | ID: lil-767321

RESUMO

Relata-se o caso de uma criança com síndrome do QT longo congênito e Tetralogia de Fallot, submetidaa denervação simpática por videotoracoscopia, para controle de tempestades arrítmicas e diminuição do númerode choques do cardioversor-desfibrilador implantável...


We report the case of a child with congenital long QT syndrome and Tetralogy of Fallot submittedto sympathetic denervation by videolaparoscopy to control arrhythmic storms and decrease the number ofimplantable cardioversor-defibrillator chocks...


Assuntos
Humanos , Criança , Arritmias Cardíacas/complicações , Síndrome do QT Longo/terapia , Tetralogia de Fallot/terapia , Desfibriladores Implantáveis , Ecocardiografia , Eletrocardiografia Ambulatorial , Simpatectomia/enfermagem
18.
Acta cir. bras ; 28(7): 543-550, July 2013. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-679088

RESUMO

PURPOSE: To assess the effectiveness of bipolar epicardial atrial pacing using an active fixation bipolar endocardial lead implanted on the atrial surface in an experimental model. METHODS: A total of ten Large White adult pigs underwent pacemaker implantation under general anesthesia. Atrial pacing and sensing parameters were obtained at the procedure, immediate postoperative period and on the 7th and the 30th postoperative in unipolar and bipolar configurations. RESULTS: All procedures were successfully performed. There were no perioperative complications and no early deaths. Atrial pacing and sensing parameters for both unipolar and bipolar modes remained stable throughout the study. We observed a progressive increase in atrial thresholds, ranging from 0.49 ± 0.35 (at implantation) to 1.86 ± 1.31 volts (30th postoperative day), in unipolar mode. Atrial impedance measurements decreased slightly over time, ranging from 486.80 ± 126.35 Ohms (at implantation) to 385.0 ± 80.52 Ohms (30th postoperative day). Atrial sensing measures remained stable from the immediate postoperative period until the end of the study. CONCLUSION: The bipolar active fixation endocardial lead implanted epicardially can provide stable conditions of pacing and sensing parameters throughout the postoperative follow-up.


Assuntos
Animais , Estimulação Cardíaca Artificial/métodos , Eletrodos Implantados , Desenho de Equipamento/métodos , Átrios do Coração/cirurgia , Marca-Passo Artificial , Esteroides/administração & dosagem , Átrios do Coração/fisiopatologia , Duração da Cirurgia , Período Pós-Operatório , Reprodutibilidade dos Testes , Propriedades de Superfície , Suínos , Fatores de Tempo , Resultado do Tratamento
19.
In. Timerman, Sergio; Dallan, Luís Augusto Palma; Geovanini, Glaucylara reis. Síndromes coronárias agudas e emergências cardiovasculares / Acute coronary syndromes and cardiovascular emergencies. São Paulo, Atheneu, 2013. p.31-42.
Monografia em Português | LILACS | ID: lil-719900
20.
Rev. bras. cir. cardiovasc ; 25(3): 406-409, jul.-set. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-565009

RESUMO

Descrevemos os casos de duas gestantes portadoras de cardiomiopatia hipertrófica com alto risco de morte súbita arrítmica, que foram submetidas a implante de cardioversor-desfibrilador automático (CDI) no intercurso da gestação. O momento para a realização do procedimento e os cuidados necessários para o implante do CDI durante a gestação são discutidos e foram os principais objetivos deste relato.


We describe the successful implantation of a cardioverter-defibrillator (ICD) in two pregnant women with hypertrophic cardiomyopathy at high risk. The indication of ICD and the necessary care for ICD implantation during pregnancy are discussed and were the main objectives of this case report.


Assuntos
Adolescente , Feminino , Humanos , Gravidez , Adulto Jovem , Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Morte Súbita Cardíaca/prevenção & controle , Complicações Cardiovasculares na Gravidez/terapia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA